摘要

为解决罗兰光栅光谱成像不?#23383;?#25509;读取、平面场凹面光栅成像算法复杂等问题,设计了一种基于全息凹面光栅原理的用于特定蛋白分析仪生化检测的分光光度计。该结构?#26376;?#20848;光栅为基底,采?#30431;?#36879;镜作为过渡元件,将罗兰光栅的曲面成像过渡成平场光谱,同时采用光学设计软件Zemax对该结构进行模拟和优化。优化结果表明,分光光度计能够实现光谱平场化,工作波段为320~800 nm,最高分辨率可达0.5 nm,整体分辨率优于1.7 nm,可被光电二极管阵列直接读取,结构特性满足特定蛋白分析仪的测量要求。样机实验结果与模拟结果一致,仪器重复性、准确?#21462;?#31283;定性及线性度均达到行业标准。

Abstract

In order to solve such problems as difficulty in directly reading the spectral imaging of Rowland grating and the complex imaging algorithm for flat-field concave gratings, we design a spectrophotometer based on principle of the holographic concave grating for biochemical detection of specific protein analyzers. This structure is based on the Rowland grating, and uses two lenses as the transition elements to transform the curved surface imaging of Rowland grating to the flat-field spectrum. Meanwhile, we simulate and optimize the structure with the optical design software Zemax. The optimization results show that the spectrophotometer whose working band is 320-800 nm with the highest resolution of 0.5 nm and the overall resolution of 1.7 nm, can be directly read by the photodiode array and can achieve plane spectrum. The structural characteristics meet the measurement requirements of specific protein analyzers. The experimental results of the prototype are consistent with the simulation results, and the repeatability, accuracy, stability, and linearity of the instrument are all up to the industry standards.

Newport宣传-MKS新实验室计划
补充资料

DOI:10.3788/AOS201939.0830002

所属栏目:光谱学

基金项目?#33322;?#33487;省自然科学基金青年基金(BK20160190);

收稿日期:2019-03-13

修改稿日期:2019-04-23

网络出版日期:2019-08-01

作者单位    点击查看

李俊纬?#33322;?#21335;大学物联网工程学院, 江苏 无锡 214122
倪屹?#33322;?#21335;大学物联网工程学院, 江苏 无锡 214122
郭瑜?#33322;?#21335;大学物联网工程学院, 江苏 无锡 214122
张啸天?#33322;?#21335;大学物联网工程学院, 江苏 无锡 214122
钟道鸿?#33322;?#21335;大学物联网工程学院, 江苏 无锡 214122
樊俊星?#20309;?#38177;克劳斯麦迪医疗仪器有限公司, 江苏 无锡 214028

联系人作者:倪屹([email protected])

备注?#33322;?#33487;省自然科学基金青年基金(BK20160190);

【1】Liu L J, Xu H Y, Zhao F et al. Application of UV-Vis spectrophotometry in quantitative monitoring sustained release of 2, 3, 5-triiodobenzoic acid. Journal of Textile Research. 40(2), 20-25(2019).
刘来俊, 徐海燕, 赵帆 等. 紫外-可见分光光度法在定?#32771;?#27979;2, 3, 5-三碘苯甲酸缓释中的应用. 纺织学报. 40(2), 20-25(2019).

【2】Chen H F, Gong Y, Luo C et al. Design of prism-grating imaging spectrometer with eliminating spectral line curvature. Acta Optica Sinica. 34(9), (2014).
陈洪福, 巩岩, 骆聪 等. 消谱线弯曲棱镜-光栅?#32479;?#20687;光谱仪设计. 光学学报. 34(9), (2014).

【3】Chen Y and Wang Y M. Optical design of prism spectrometer system with a small incident angle. Acta Optica Sinica. 33(9), (2013).
陈杨, 王跃明. 小入射角棱镜成像光谱仪光学系统设计. 光学学报. 33(9), (2013).

【4】Chen K and Xiao Z X. Research and design of biochemical analyzer optical system. Optical Technique. 32(s1), 374-376, 379(2006).
陈宽, 萧泽新. 生化分析仪光学系统的研究与设计. 光学技术. 32(s1), 374-376, 379(2006).

【5】Ren X D, Lei W H, Zeng L Q et al. Thermal and mechanical effect of the narrow band filter irradiated by laser at oblique incidence. Acta Photonica Sinica. 47(11), (2018).
任晓东, 雷武虎, 曾凌清 等. 激光斜入射窄带滤光片的热力效应. 光子学报. 47(11), (2018).

【6】Liu Q, Zhou J S, Nie Y F et al. Study of spectral property and measurement of linear variable filters. Spectroscopy and Spectral Analysis. 35(4), 1142-1145(2015).
柳青, 周锦松, 聂?#21697;?等. 线性渐变滤光片光谱分光特性?#20985;?#27979;方法研究. 光谱学与光谱分析. 35(4), 1142-1145(2015).

【7】Li C M, Wu J H and Tang M X. Design of flat field holographic concave grating. Laser Journal. 26(2), 57-58(2005).
李朝明, 吴建宏, 唐敏学. 平场全息凹面光栅的设计. 激光杂志. 26(2), 57-58(2005).

【8】Cheng L, Chen Y P, Zhu R B et al. Optimum design of flat-field holographic concave grating for micro-spectrometers. Journal of Zhejiang University (Engineering Science). 42(2), 312-316(2008).
程梁, 陈燕平, 朱若波 等. 微型光谱仪平场全息凹面光栅的优化设计. 浙江大学学报(工学版). 42(2), 312-316(2008).

【9】Xia G, Wu S, Huang S et al. Design of crossed-asymmetric Czerny-Turner spectrometer optical system. Acta Photonica Sinica. 46(4), (2017).
夏果, 吴骕, 黄禅 等. 交叉非对称型Czerny-Turner光谱仪光学系统设计. 光子学报. 46(4), (2017).

【10】Yang X Q. Design of testing system of multifunctional medical analyzer. Nanjing: Nanjing University of Science and Technology. (2017).
杨晓琦. 多功能医疗分析仪检测系统设计. 南京: 南京理工大学. (2017).

【11】Wang H. Research on the key technology of automatic biochemical analyzer. Luoyang: Henan University of Science and Technology. (2017).
王虎. 全自动生化分析仪关键技术研究. 洛阳: 河南科技大学. (2017).

【12】Kong W P, Wu T, Nie W et al. Influence of water vapor absorption on NO3 radical measurement based on broad-band cavity-enhanced absorption spectroscopy. Acta Optica Sinica. 39(2), (2019).
孔维平, 吴涛, 聂玮 等. 水汽吸收对基于宽带腔增强吸收光谱的NO3?#26434;?#22522;测量的影响. 光学学报. 39(2), (2019).

【13】Hao A H, He F T, Li L B et al. Design of wide-field and flat-spectrum holographic concave grating spectrometer. Acta Optica Sinica. 38(2), (2018).
郝爱花, 贺锋涛, 李立波 等. 宽场平谱面全息凹面光栅光谱仪的设计. 光学学报. 38(2), (2018).

【14】Xu F, Yan H, Zhang Y H et al. Ultra-narrow linewidth spectral filtering technology based on double gratings. Chinese Journal of Lasers. 44(8), (2017).
许放, 颜宏, 张永红 等. 基于双光栅的超窄线宽光谱滤波技术. 中国激光. 44(8), (2017).

【15】Zhao X L. Bayanheshig, Li W H, et al. Integrated design to complement aberrations of spherical focusing mirrors and concave holographic gratings in spectrometers. Acta Optica Sinica. 36(6), (2016).
赵旭龙. 巴音贺希格, 李文昊, 等. 光谱仪中球面聚焦反射镜和凹面全息光栅像差互补的一体化设计. 光学学报. 36(6), (2016).

【16】Noda H, Namioka T and Seya M. Geometric theory of the grating. Journal of the Optical Society of America. 64(8), 1031-1036(1974).

【17】Zhao X L. Study on design method extend and testing technology of holographic concave gratings. Changchun: University of Chinese Academy of Sciences. (2017).
赵旭龙. 全息凹面光栅设计理论扩展及曝光系统检测技术研究. 长春: 中国科学院大学. (2017).

【18】He W X, Wen Z Y and Zhou Y. Design and performance test of practical near infrared micro-spectrometer. Laser & Optoelectronics Progress. 54(6), (2017).
何文馨, 温志渝, 周颖. 实用化微型近红外光谱分析仪的设计与性能测试. 激光与光电子学进展. 54(6), (2017).

【19】China Food and Drug Administration. (2017).
国家食品药品监督管理总局. (2017).

引用该论文

Junwei Li, Yi Ni, Yu Guo, Xiaotian Zhang, Daohong Zhong, Junxing Fan. Structural Design and Performance Analysis of Specific Protein Analyzer Based on Concave Grating[J]. Acta Optica Sinica, 2019, 39(8): 0830002

李俊纬, 倪屹, 郭瑜, 张啸天, 钟道鸿, 樊俊星. 基于凹面光栅的特定蛋白分析仪结构设计及性能分析[J]. 光学学报, 2019, 39(8): 0830002

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF

一肖中特公式